Further Information
HAVCR1; TIM1; TIMD1; HAVCR; Hepatitis A Virus Cellular Receptor 1; T Cell Immunoglobulin And Mucin Domain-Containing Protein 1; T-cell immunoglobulin mucin receptor 1
2h, 40min
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 2 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.
195.31-50000pg/mL
48T, 96T, 96T?5, 96T?10, 96T?100
Kidney Injury Molecule 1
Double-antibody Sandwich
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Kidney Injury Molecule 1 (Kim1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Kidney Injury Molecule 1 (Kim1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Tumor immunity;Infection immunity;Kidney biomarker;
Tissue homogenates, urine, cell culture supernates and other biological fluids
The minimum detectable dose of this kit is typically less than 26.3pg/mL
This assay has high sensitivity and excellent specificity for detection of Kidney Injury Molecule 1 (Kim1).
No significant cross-reactivity or interference between Kidney Injury Molecule 1 (Kim1) and analogues was observed.
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
The microplate provided in this kit has been pre-coated with an antibody specific to Kidney Injury Molecule 1 (Kim1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Kidney Injury Molecule 1 (Kim1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Kidney Injury Molecule 1 (Kim1) level in the sample or standard.;
Q5QNS5