CLIA Kit for Adrenocorticotropic Hormone (ACTH)

Cloud-Clone Corp.
Product Code: CCA836Ra
Product Group: CLIA Kits

CodeSizePrice
CCA836Ra-24T24T£273.00
Quantity:
CCA836Ra-48T48T£455.00
Quantity:
CCA836Ra-96T96T£637.00
Quantity:
CCA836Ra-96T*596T*5£2,760.00
Quantity:
CCA836Ra-96T*1096T*10£5,186.00
Quantity:
Prices exclude any Taxes / VAT

Overview

Regulatory Status: RUO
Target Species: Rat
Application: Chemiluminescent Immunoassay (CLIA)

Images

1 / 1

Further Information

Alternative Names:
Corticotropin; Adrenocorticotropin
Assay length:
2h
Assay Procedure Summary:
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
7. Read RLU value immediately.
Detection range:
11.72-3000pg/mL
Format:
48T, 96T, 96T?5, 96T?10, 96T?100
Item Name:
Adrenocorticotropic Hormone
Method:
Competitive Inhibition
Precision:
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Adrenocorticotropic Hormone (ACTH) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Adrenocorticotropic Hormone (ACTH) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Research Area:
Endocrinology;Hormone metabolism;Urology;
Sample type:
Serum, plasma and other biological fluids
Sensitivity:
The minimum detectable dose of this kit is typically less than 4.52pg/mL
Specificity:
This assay has high sensitivity and excellent specificity for detection of Adrenocorticotropic Hormone (ACTH).
No significant cross-reactivity or interference between Adrenocorticotropic Hormone (ACTH) and analogues was observed.
Stability:
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Test Principle:
The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Adrenocorticotropic Hormone (ACTH). A competitive inhibition reaction is launched between biotin labeled Adrenocorticotropic Hormone (ACTH) and unlabeled Adrenocorticotropic Hormone (ACTH) (Standards or samples) with the pre-coated antibody specific to Adrenocorticotropic Hormone (ACTH). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Adrenocorticotropic Hormone (ACTH) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Adrenocorticotropic Hormone (ACTH) level in the sample or standard.
Uniprot ID:
P01194